Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Magn Reson Med ; 66(2): 605-8, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21433067

RESUMO

Laser atomic magnetometry is a portable and low-cost yet highly sensitive method for low magnetic field detection. In this work, the atomic magnetometer was used in a remote-detection geometry to measure the relaxivity of aqueous gadolinium-diethylenetriamine pentaacetic acid Gd(DTPA) at the Earth's magnetic field (40 µT). The measured relaxivity of 9.7±2.0 s(-1) mM(-1) is consistent with field-cycling experiments measured at slightly higher magnetic fields, but no cryogens or strong and homogeneous magnetic field were required for this experiment. The field-independent sensitivity of 80 fT Hz(-1/2) allowed an in vitro detection limit of ∼10 µM Gd(DTPA) to be measured in aqueous buffer solution. The low detection limit and enhanced relaxivity of Gd-containing complexes at Earth's field motivate continued development of atomic magnetometry toward medical applications.


Assuntos
Avaliação Pré-Clínica de Medicamentos/instrumentação , Gadolínio/análise , Gadolínio/química , Espectroscopia de Ressonância Magnética/instrumentação , Magnetometria/instrumentação , Meios de Contraste/análise , Meios de Contraste/química , Desenho de Equipamento , Análise de Falha de Equipamento , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
2.
J Magn Reson ; 199(1): 25-9, 2009 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-19406678

RESUMO

Scalar couplings of the form JI(1) x I(2) between nuclei impart valuable information about molecular structure to nuclear magnetic-resonance spectra. Here we demonstrate direct detection of J-spectra due to both heteronuclear and homonuclear J-coupling in a zero-field environment where the Zeeman interaction is completely absent. We show that characteristic functional groups exhibit distinct spectra with straightforward interpretation for chemical identification. Detection is performed with a microfabricated optical atomic magnetometer, providing high sensitivity to samples of microliter volumes. We obtain 0.1 Hz linewidths and measure scalar-coupling parameters with 4-mHz statistical uncertainty. We anticipate that the technique described here will provide a new modality for high-precision "J spectroscopy" using small samples on microchip devices for multiplexed screening, assaying, and sample identification in chemistry and biomedicine.


Assuntos
Espectroscopia de Ressonância Magnética/instrumentação , Magnetismo/instrumentação , Dispositivos Ópticos , Refratometria/instrumentação , Análise Espectral/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...